Superconducting Performance Test Facility for Large-current Conductor of Fusion Machine
Yoshikazu TAKAHASHIMasayuki OSHIKIRIKatsumi KAWANOHiromi HANAWAKouichi IMAHASHISyuuichi SEKIKiichi OHTSUHiroshi WAKABAYASHIKatsutoshi TAKANOYasuhiro UNOHiroshi TSUJI
Author information
JOURNAL FREE ACCESS

1998 Volume 33 Issue 5 Pages 323-333

Details
Abstract
The superconducting performance test facility for the 50-kA conductor of a fusion machine was completed at the Japan Atomic Energy Research Institute (JAERI). This facility consists of a 5-kW refrigeration system, 60-kA DC power-supply system, a liquid-helium dewar, and vacuum evacuation and data acquisition systems. The full-size conductor and joint sample for the ITER central solenoid (CS) model coils will be tested in this facility. The samples are cooled by a supercritical helium of from 5 to 16K and tested for an external field of up to 11 T and a 60kA current. According to these results, the operation limits of the model coil will be estimated and the fabrication technique of large coils verified. This facility has completed preliminary tests and its designed performance confirmed.