Abstract
The dissolution rate of tungsten in an alkaline etching solution containing ferricyanide was studied. The cathodic reduction of ferricyanide was controlled by mass transfer under operating conditions, so the anodic dissolution of tungsten is also limited. The reaction rate was thus fairly proportional to the ferricyanide concentration, and was increased by solution agitation.