Japanese Journal of Radiological Technology
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
AN ATTEMPT TO DESIGN CONTRAST OF BLOOD VESSEL AT MAGNIFICATION ANGIOGRAPHY
SATOSHI FUKUGAMITADASHI YOSHIMINESHINOBU YUMIBAYASUFUMI OHGATOSHIKAZU SAIDAFUMIO UENOYAMATAMOTSU OCHISHIGEKI UYAMA
Author information
JOURNAL FREE ACCESS

1984 Volume 40 Issue 7 Pages 1041-1047

Details
Abstract
Recently, magnification angiography has become popular, because of improvement in X-ray tubes and development of sensitive filmscreen system. Blood vessel contrast is affected by scattered radiation, MTF of systems and taper effect. This time we introduced one of the new functions called P (ω) composed by content rate of direct radiation, MTF of direct radiation and absorption rate of contrast medium, and tried to obtain prediction of the contrast of blood vessel filled with contrast medium. On comparing the contrast calculated from P (ω) with the contrast of the clinical radiography, we got good result and found that P (ω) was very useful.
Content from these authors
© 1984 Japanese Society of Radiological Technology
Previous article Next article
feedback