The Journal of the Japanese Society for Dental Materials and Devices
Online ISSN : 2188-4188
Print ISSN : 0286-5858
ISSN-L : 0286-5858
Original Article
Analysis of Dimensional Accuracy Variables for Maxillary Complete Denture Processed with Microwave-curing Resin
Shinsuke KOYANAGIXiao Rong WANGYutaka TAKAHASHITetsuya HABU
Author information
JOURNAL FREE ACCESS

2000 Volume 19 Issue 3 Pages 289-293

Details
Abstract
In a previous study, dentures processed with injection type microwave-curing resin and conventional type microwave-curing resin showed different dimensional accuracy. The purpose of this study was to elucidate the variables that exert the influence on dimensional change. The variables of denture base material, investment material, molding technique, microwave exposing time and bench cooling time were analyzed with robust design methods, and the conditions imposed in the study were compared. The variables affected dimensional accuracy for complete denture processed with microwave-curing resin were denture base material, investment material and microwave exposing time.
Content from these authors
© 2000 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top