Novel Configuration of Three-Stage Pulse Tube Refrigerator for Temperatures below 4K
Jin Lin GAOYoichi MATSUBARA
Author information
JOURNAL FREE ACCESS

1994 Volume 29 Issue 4 Pages 150-154

Details
Abstract
A novel multiple staging configuration for the pulse tube refrigerator is described for increase in its performance and simplicity. To decrease both regenerator loss and pulse tube loss, a regenerative tube was developed for operating the pulse tube from room temperature to liquid helium temperature. With this configuration, 3.6K of lowest temperature and 119mW of cooling capacity at 4.9K were achieved by a three-stage pulse tube refrigerator. Test results and refrigeration performance of this refrigerator are presented.