TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
Demonstration Poloidal Coil Test Facility
The Performance Test Results of the Cryogenic Cold Compressor
Masahiko SATOKatumi KAWANOEisuke TADATadao HIYAMATakashi KATOHidemasa YAMAMURAMasahiro HOSHINOSusumu SHIMAMOTOHiroshi ASAKURANobuyoshi SAJI
Author information
JOURNAL FREE ACCESS

1989 Volume 24 Issue 1 Pages 29-35

Details
Abstract
A new compact cryogenic cold compressor was developed by Japan Atomic Energy Research Institute (JAERI) in collaboration with Isikawajima-Harima Heavy Industries Co., Ltd. (IHI) in order to produce the supercritical helium below 4.2K for Demonstration Poloidal Coils (DPC) which are forced-flow cooled type superconducting pulse coils. This compressor is one of key components for DPC test facility. The cold compressor reduces pressure in liquid helium bath, which contains liquid helium of around 3, 000l, down to 0.5atm efficiently. Consequently, supercritical helium down to 3.5K is produced and supplied to the DPC coils. A centrifugal compressor with dynamic gas bearing is selected as a compressor mechanism to realize high adiabatic efficiency and large flow rate. In this performance tests, the compressor was operated for 220h at saturated condition from 0.5 to 1.0atm without any failure. High adiabatic efficiency (more than 60%) is achieved with wide flow range (25-65g/s) and the design value is fully satisfied. The compressor can rotate up to 80, 000rpm at maximum then the coil supply temperature of supercritical helium is 3.5K.
Content from these authors
© Cryogenic Association of Japan
Previous article Next article
feedback
Top