Dental Journal of Iwate Medical University
Online ISSN : 2424-1822
Print ISSN : 0385-1311
ISSN-L : 0385-1311
Originals
Practical marginal fitness of fixed bridge
Hiroshi TakahashiKazuo SeinoTsukasa ShioyamaRyuzoh KikutaAkira HatanoKanji Ishibashi
Author information
JOURNAL FREE ACCESS

1982 Volume 7 Issue 1 Pages 34-43

Details
Abstract

The purpose of presenting paper is to demonstrate the influencing factors of the marginal fitness of fixed bridge.

Two cases of fixed bridge were surgically removed without destroying any components. One of fixed bridge was a posterior bridge as in 7-5 4|, and abutments were made with full cast crowns. Another one of fixed bride was an anterior bride as in 1|-2, and abutments were made with porcelain fused to metal crowns. Those fixed bridge were sectioned mesio-distally and bucco-lingually, and were measured the width of the cement line under the microscope.

The following observation were made,

1, The average width of cement line at the crown margins of 4|, 5|, 7| were 265μm, 260μm, 340μm, and 1|, |2 were 300μm, 405μm.

2, Overhanging margins and excessive or short margins were observed.

3, Inadequate margins fitness were due to lack of accurate therapeutic technique.

Content from these authors
1982 The Dental Society of Iwate Medical University
Previous article Next article
feedback
Top