Computer-Aided Diagnostic (CAD) Scheme by Use of Contralateral Subtraction Technique
—Application to Detection of Acute Cerebral Infarctions in Brain Computed Tomography (CT)—
Hiroyuki NagashimaTetsumi Harakawa
Author information
JOURNAL FREE ACCESS

2008 Volume 128 Issue 11 Pages 1687-1695

Details
Abstract
We developed a computer-aided diagnostic (CAD) scheme for detection of subtle image findings of acute cerebral infarction in brain computed tomography (CT) by using a contralateral subtraction technique. In our computerized scheme, the lateral inclination of image was first corrected automatically by rotating and shifting. The contralateral subtraction image was then derived by subtraction of reversed image from original image. Initial candidates for acute cerebral infarctions were identified using the multiple-thresholding and image filtering techniques. As the 1st step for removing false positive candidates, fourteen image features were extracted in each of the initial candidates. Halfway candidates were detected by applying the rule-based test with these image features. At the 2nd step, five image features were extracted using the overlapping scale with halfway candidates in interest slice and upper/lower slice image. Finally, acute cerebral infarction candidates were detected by applying the rule-based test with five image features. The sensitivity in the detection for 74 training cases was 97.4% with 3.7 false positives per image. The performance of CAD scheme for 44 testing cases had an approximate result to training cases. Our CAD scheme using the contralateral subtraction technique can reveal suspected image findings of acute cerebral infarctions in CT images.
Content from these authors
© 2008 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback
Top